本公司产品仅供体外研究使用,不用于临床诊断

PE/Cyanine5.5 Anti-Mouse F4/80 Antibody[CI:A3-1]

规格: / 25μg / 100μg
价格: / ¥1080 / ¥3000

货号:E-AB-F0995UI

应用: FCM

Isotype: Rat IgG2b, κ

宿主: Rat

  • 详情
  • Antigen Information

    Alternate Names Adhesion G protein-coupled receptor E1,Adgre1,Cell surface glycoprotein F4/80,EGF-like module receptor 1,Adgre1,Emr1, Gpf480
    Swissprot Q61549
    References
    1. Austy JM and Gordon S. 1981. Eur. J. Immunol. 11:805.
    2. Hume DA, et al. 1983. J. Exp. Med. 158:1522.
    3. Ruedl C, et al. 1996. Eur. J. Immunol. 26:1801.
    4. McKnight AJ, et al. 1996. J. Biol. Chem. 271:486.
    5. Lin HH, et al. 2005. J. Exp. Med. 201:1615.

    Product Details

    Form Liquid
    Clone No. CI:A3-1 (See Other Available Formats)
    Host Rat
    Isotype Rat IgG2b, κ
    Isotype Control PE/Cyanine5.5 Rat IgG2b, κ Isotype Control[LTF-2] [Product E-AB-F09843I]
    Reactivity Mouse
    Application FCM (See the Application Description)
    Storage Buffer Phosphate buffered solution, pH 7.2, containing 0.09% sodium azide and 1% BSA.
    Recommended Use Each lot of this antibody is quality control tested by flow cytometric analysis. Please check your vial before the experiment. Since applications vary, the appropriate dilutions must be determined for individual use. We suggest each investigator should titrate the reagent to obtain optimal results [The recommended concentration is 0.1-1 μg/106 cells in 100 μL volume].
    Shipping Biological ice pack at 4℃
    Stability & Storage Keep as concentrated solution.
    Store at 2~8°C and protected from prolonged exposure to light. Do not freeze.
    Centrifuge before opening to ensure complete recovery of vial contents.
    This product is guaranteed up to one year from purchase.
    Conjugation PE/Cyanine5.5
    PE/Cyanine5.5 is designed to be excited by the Blue (488 nm), Green (532 nm) and yellow-green (561 nm) lasers and detected using an optical filter centered near 690 nm (e.g., a 690/50 nm bandpass filter).

    Recommended Use

    Each lot of this antibody is quality control tested by flow cytometric analysis. Please check your vial before the experiment. Since applications vary, the appropriate dilutions must be determined for individual use. We suggest each investigator should titrate the reagent to obtain optimal results [The recommended concentration is 0.1-1 μg/106 cells in 100 μL volume].

    References

    1. Austy JM and Gordon S. 1981. Eur. J. Immunol. 11:805.
    2. Hume DA, et al. 1983. J. Exp. Med. 158:1522.
    3. Ruedl C, et al. 1996. Eur. J. Immunol. 26:1801.
    4. McKnight AJ, et al. 1996. J. Biol. Chem. 271:486.
    5. Lin HH, et al. 2005. J. Exp. Med. 201:1615.

    Additional Products

    Catalog No. Product Name Clone No.
    E-AB-F09950 AF/LE Purified Anti-Mouse F4/80 Antibody[CI:A3-1]